IOLAN SDS HV/LDC Terminal Server
Perle Essential Network Connectivity Terminal servers, Device servers, Console servers, PCI Serial Cards Secure and reliable serial connectivity solutions
 
Specialix Chase Research
Products > Terminal Server > IOLAN SDS HV/LDC

IOLAN Electric Utility Terminal Server

SDS HV/LDC Terminal Server

  • 8, 16 and 32 serial ports on RJ45 - software selectable RS232/422/485
  • Advanced security features for NERC CIP critical cyberasset substation compliance
  • Substation hardened to meet the requirements for harsh electrical utility and industrial applications
  • Universal high voltage power supply: nominal 125v DC / 250v DC or 115v AC / 230v AC
  • Dual Feed low voltage power supply: nominal 24v DC /48v DC
  • 10/100/1000 Ethernet
  • Built-in failsafe alarm relay

  Get a Quote
Bookmark this Page

Hardware Specifications - IOLAN SDSC Electric Utility Terminal Servers

 
SDS8
HV
SDS8
DHV
SDS16
HV
SDS16
DHV
SDS32
HV
SDS32
DHV
SDS8
LDC
SDS16
LDC
Processor
MPC8349E, 400 Mhz, 750 MIPS
Memory
RAM MB
64
64
64
64
128
128
64
64
Flash MB
16
16
16
16
16
16
16
16
Interface Ports
Number of Serial Ports
8
8
16
16
32
32
8
16
Serial Port Interface
Software selectable RS232 / RS485 / RS422 DTE on RJ45 - RS485: full and half duplex
Sun / Solaris
Sun break safe
Serial Port Speeds
50bps to 230Kbps with customizable baud rate support
Data Bits
5,6,7,8, 9-bit protocol support
Parity
Odd, Even, Mark, Space, None
Flow Control
Hardware, Software, Both
Local Console Port
RS232 on RJ45 with DB9 adapter ( provided )
Network
10/100/1000-base TX Ethernet RJ45
Software selectable Ethernet speed 10/100/1000, Auto
Software selectable Half/Full/Auto duplex
Failsafe Alarm Relay
3A@24v DC. Normally open contacts closed by IOLAN when active and opened upon alarm condition or power failure
Power
Power Supply
Terminal Block with screw terminals accommodating a #6 ring terminal for each power source. Protective cover provided
Plugable Terminal Blocks with screw terminals accommodating 28 - 12 AWG wire sizes
Nominal Input Voltage
125V DC / 250V DC or 100V AC / 240V AC
24v DC / 48v DC
Input Voltage Range
88-300V DC or 85-265V AC
18 - 72v DC
AC Input Frequency
47-63Hz
Current Consumption @ 125v DC (Amps)
0.06
0.07
0.08
0.08
0.13
0.13
N/A
N/A
Current Consumption @ 250v DC (Amps)
0.04
0.04
0.05
0.05
0.07
0.07
N/A
N/A
Current Consumption @ 115v AC (Amps)
0.13
0.15
0.07
0.2
0.26
0.28
N/A
N/A
Current Consumption @ 230v AC (Amps)
0.09
0.11
0.12
0.14
0.16
0.19
N/A
N/A
Current Consumption @ 18v DC (Amps)
N/A
N/A
N/A
N/A
N/A
N/A
0.4
0.55
Current Consumption @ 24v DC (Amps)
N/A
N/A
N/A
N/A
N/A
N/A
0.3
0.4
Current Consumption @ 48v DC (Amps)
N/A
N/A
N/A
N/A
N/A
N/A
0.2
0.25
Current Consumption @ 72v DC (Amps)
N/A
N/A
N/A
N/A
N/A
N/A
0.15
0.18
Typical Power Consumption (Watts)
9
10
12
12.5
17
17.5
11
13
Chassis Ground
Grounding screw for a #10 ring terminal
Indicators
LEDs
Power
System Ready
Network Link activity
Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output ( BTU/HR )
30.7
34.12
40.9
42.7
58
59.7
37.6
44.4
MTBF ( Hours )
126,121
144,323
105,368
117,779
82,325
89,711
126,302
105,495
Operating Temperature
-40C ambient for 16 hours and +70C ambient for 16 hours without use of fans
Storage Temperature
-40C to 85C, -40F to 185F
Humidity
5 to 95% (non condensing) for both storage and operation.
Case
SECC Zinc plated sheet metal (1 mm)
Ingress Protection Rating
IP30
Mounting
1U - 19" rack, front and rear mounting hardware included.
DIN Rail mounting kit optional
Product Weight and Dimensions
Weight
3.20 kg
3.38 kg
3.22 kg
3.40 kg
3.40 kg
3.58 kg
3.16 kg
3.18 kg
Dimensions
1U Rack form factor - 26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in)
Packaging
Shipping Dimensions
59 x 36 x 9 (cm), 23 x 14 x 3.5 (in)
Shipping Weight
4.00 kg
4.18 kg
4.20 kg
4.20 kg
4.20 kg
4.38 kg
3.96 kg
3.98 kg
Regulatory Approvals
Emissions
Power Line conducted: IEC 61850-3 Sec 5.8, IEC 61000-6-4, CISPR 16-2-3, CISPR 22, FCC Part 15,
Subpart B, Class B
Telecom Line conducted: IEC 61000-6-4, CISPR 22
Radiated: IEC 61850-3 Sec 5.8, IEC 61000-6-4, CISPR 16-2-3, CISPR 22, FCC Part 15, Subpart B, Class B
IEC61000-3-2 Harmonic Current Emissions
IEC61000-3-3 Flicker emissions
EMC Interface Immunity

- IEC 61850-3 ( substations )
- IEEE 1613 ( substations ) (C37.90.x )

Applies to all ports, signal and power connections
ESD: IEC61000-4-2, 8Kv Contact / 15Kv Air
Radiated RFI: IEC61000-4-3, 20 V/m ( 80M-1G )
Fast Transients / Burst: IEC61000-4-4, 4Kv Mains , I/O
Surge : IEC61000-4-5
4Kv AC line to Gnd, 2Kv AC Line to Line,
2Kv DC line to Gnd, 1 Kv DC Line to Line,
RS232 = balanced, ethernet = unbalanced
Conducted RF: IEC61000-4-6, 10 Vrms
Magnetic Field: IEC61000-4-8, 100 A/m, 1000 A/m (1 sec)
Dips and Interrupts: IEC61000-4-11, Criteria A/B/C
Oscillatory: EN61000-4-12, 2.5Kv common and differential mode
Low Frequency conducted: EN61000-4-16, 30V 60s, 300V 1s,15Hz-150KHz @ level 3
Standard Safety Certifications
IEC 60950-1, First Edition (2001-10) and EN60950-1:2001, CB scheme.
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component)
Other
RoHS - 2002/95/EC Directive
WEEE - 2002/96/EC Directive
CCATS - G052929
ECCN - 5A992A
HTSUS Number: 8471.80.1000
Perle Lifetime Warranty
Serial Connector Pinout

IOLAN DTE

RJ45Socket

RJ45 Socket

IOLAN
RJ45 Socket
Direction
RS232
RS422
RS485
Full Duplex
RS485
Half Duplex
1
right arrow
RTS
TXD+
TXD+
Data+
2
right arrow
DTR
3
right arrow
TXD
TXD-
TXD-
Data-
4
---
GND
GND
GND
GND
5
---
GND
GND
GND
GND
6
left arrow
RXD
RXD+
RXD+
7
left arrow
DSR
8
left arrow
CTS
RXD-
RXD-

A "rolled" CAT5 cable will automatically perform DTE to DCE crossover

Optional Perle adapters for use with straight thru CAT5 cabling

» Back to top

 

Terminal Servers | Console Server | Device Server | Ethernet IO Device Server | Serial Card | About Serial to Ethernet Solutions | Ethernet Media Converters | About Ethernet to Fiber Solutions
Site Map | Legal Information | Privacy Policy | Contact Us
Copyright © 2010 Perle. All Rights Reserved

[ International Sites ]