| Indicators |
| Power / TST |
This green LED is turned on when power is applied to the media converter.
Otherwise it is off. The LED will blink when in Loopback test mode. |
| Fiber link on / Receive activity (LKF) |
This green LED is operational only when power is applied. The LED is
on when the 1000Base-X link is on and flashes with a 50% duty cycle when
data is received. The LED will slow blink when the 1000Base-X interface
has been taken down as a result of a fault on the 1000Base-T interface. |
| Copper link on / Receive activity (LKC) |
This green LED is operational only when power is applied. The LED is
on when the 1000Base-T link is on and flashes with a 50% duty cycle when
data is received. The LED will slow blink when the 1000Base-T interface
has been taken down as a result of a fault on the 1000Base-T interface. |
| Switches: On-Board |
| Auto-Negotiation |
Enabled (Default - Up) In this mode the 1000Base-X
and the 1000Base-T will negotiate to the HCD of the two link partners.
The 1000Base-X will link up after the negotiation is completed and the
1000Base-T has linked up.
Disabled - The 1000Base-X will not use auto negotiation. The
1000Base-T will negotiate to the HCD of the Switch settings and the link
partner. |
| Link Mode |
Link Mode provides a transparency to the state of the copper link allowing
for simplified trouble shooting from the devices connected to the media
converter.
Normal (Default – Up)
With Fiber Auto Negotiation enabled
when the 1000Base-T link goes down the 1000Base-X link is brought
down. The 1000Base-X link will advertise Remote Fault (Link Fault).
With
Fiber Auto Negotiation disabled the state of the 1000Base-T link has
no effect on the 1000Base-X link.
Smart Link Pass Through (Down)
With Fiber Auto Negotiation
enabled the behavior is as follows. When the 1000Base-T link goes
down the 1000Base-X link is brought down. The 1000Base-X link will
advertise Remote Fault (Link Fault). When Remote Fault (Link Fault)
is received on the 1000Base-X interface the 1000Base-T transmitter
will be turned off. When the 1000Base-T receiver is off the 1000Base-X
transmitter will be turned off. When the 1000Base-X receiver goes off
the 1000Base-T transmitter will be turned off.
With Fiber Auto-Negotiation disabled the behavior is as follows. When
the 1000Base-T receiver is off the 1000Base-X transmitter will be turned
off. When the 1000Base-X receiver goes off the 1000Base-T transmitter
will be turned off. |
| Pause |
When Fiber Auto Negotiation is disabled Pause should only be enabled
when all devices connected to the media converter support pause.
Enabled(Default) - The Media converter will advertise Pause capable,
Asymmetric pause not needed during Auto-Negotiation..
Disabled - The Media converter will advertise that it does not have
Pause capability during Auto-Negotiation. |
| Fiber Fault Alert |
The Fiber Fault Alert switch has meaning when Auto-Negotiation is
disabled
Enabled (Default - Up)
When the 1000Base-X receiver is off the 1000Base-X transmitter is turned
off. Periodically the 1000Base-X receiver will be turned on for a short
period to allow the condition to clear if the 1000Base-X link partner
is using a similar feature.
Disabled (Down) |
| Duplex |
Full (Default-Up) - The media converter will advertise Full
Duplex Capable, Half Duplex Capable.
AUTO (Down) -The Media converter will advertise Full Duplex
Not Capable, Half Duplex Capable. |
| Remote Loopback |
The media converter can perform a loopback on the 1000Base-X fiber
interface.
Disabled (Default - Up)
Enabled - The 1000Base-X receiver is looped to the 1000Base-X
transmitter. The 1000Base-T transmitter is taken off the interface.
|
| Connectors |
| 1000Base-T |
RJ45 connector, 4 pair
CAT 5 UTP cable or cable
|
| Magnetic Isolation |
1.5kv |
| Packet Transmission Characteristics |
| Bit Error Rate (BER) |
<10 -12 |
| Environmental Specifications |
| Operating Temperature |
0° C to 50° C (32° F to 122° F) |
| Storage Temperature |
minimum range of -25° C to 70° C (-13° F to 158° F) |
| Operating Humidity |
5% to 90% non-condensing |
| Storage Humidity |
5% to 95% non-condensing |
| Operating Altitude |
Up to 3,048 meters (10,000 feet) |
| Heat Output ( BTU/HR ) |
10.2 |
| MTBF (Hours) |
609,000 |
| Mechanical - Hot Swapping Card |
| Edge Connecter |
32 pin DIN 41612 / IEC 60603-2 Type B/2 Male. Fist make, last break for ground and power |
| Card insertion and removal |
Captive thumb screws enable fast insertion and removal. Can be further tighten with a screwdriver. |
| Product Weight |
| Weight |
0.15 kg, 0.33 lbs |
| Packaging |
| Shipping Weight |
0.33 kg, .73 lbs |
| Shipping Dimensons |
203 x 38 x 152 mm, 8 x 1.5 x 6 inches |
| Regulatory Approvals |
| Emissions |
FCC Part 15 Class A, EN55022 Class A |
| CISPR 22 Class A |
| EN61000-3-2 |
| Immunity |
EN55024 |
| Electrical Safety |
UL 60950-1 |
| EN60950 |
| CE |
| Laser Safety |
EN 60825-1:2007 |
| Fiber optic transmitters on this device meet Class 1 Laser safety requirements
per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11. |
| Environmental |
RoHS - 2002/95/EC Directive |
| WEEE - 2002/96/EC Directive |
| Reach compliant |
| Other |
ECCN: 5A991A |
| HTSUS Number: 8517.62.0050 |
| Perle Lifetime warranty |