IOLAN MDC4 |
IOLAN MDC8 |
| Processor |
MPC8349E, 400 Mhz, 750 MIPS |
Memory |
| RAM MB |
32 |
64 |
| Flash MB |
16 |
16 |
Interface Ports |
| Number of Serial Ports |
4 |
8 |
| Serial Port Interface |
RS232 DTE on RJ45 |
| Sun / Solaris |
Yes |
| Serial Port Speeds * |
50bps to 230Kbps with customizable
baud rate support |
Data Bits * |
5,6,7,8, 9-bit protocol support |
Parity * |
Odd, even, Mark, Space, None |
Flow Control * |
Hardware, software, both |
| Serial Port Protection |
Galvanic Isolation - basic insulation
of 1500Vac |
Recessed ports satisfies UL “Test
Finger” |
15Kv Electrostatic Discharge Protection
( ESD ) |
| Network |
10/100/1000 base TX Ethernet RJ45 |
Software selectable Ethernet speed
10/100 Auto |
Software selectable Half/Full/Auto
duplex |
Ethernet Isolation |
1.5Kv Magnetic Isolation |
Power |
| Power Supply |
USA models |
IEC320-C13 to NEMA 5-15P line
cord |
UK models |
IEC320-C13 to BS1363 line cord |
EU models |
IEC320-C13 to CEE 7/7 Schuko |
South Africa Models |
IEC320-C13 to BS546 line
cord |
Australia models |
IEC320-C13 to AS3112 line
cord |
|
| Nominal Input Voltage: |
110/230v AC |
| Input Voltage Range: |
100-240v AC |
| AC Input Frequency: |
47-63Hz |
| Current Consumption @ 100v ( Amps ) |
0.21 |
0.25 |
| Current Consumption @ 240v ( Amps ) |
0.13 |
0.14 |
| Typical Power Consumption ( Watts ) |
12 |
15.5 |
Power Line Protection |
Fast transients: 1 KV ( EN61000-4-4
Criteria B ) |
Surge: 2KV ( EN61000-4-5 common mode),
1KV ( EN61000-4-5 differential and common modes |
Indicators |
LEDs |
Power |
Systems Ready |
Network Link Activity |
Environmental Specifications |
| Heat Output ( BTU/HR ) |
40.95 |
52.9 |
| MTBF( Hours ) |
130767 |
125287 |
| Operating Temperature |
0C to 55C, 32F to 131F |
| Storage Temperature |
-40C to 85C, -40F to 185F |
| Humidity |
5 to 95% (non condensing) for both
storage and operation. |
| Case |
Painted Aluminum |
| Ingress Protection Rating |
IP40 |
| Mounting |
Universal mounting plate for
mounting on a flat wall or hospital head-wall systems |
Product Weight and
Dimensions |
| Dimensions |
25.9 x 27.3 x 5.0 cm |
| Weight |
1.4 kg |
1.4 kg |
Packaging |
| Shippng Weight |
34.5 x 36.5 x 9.6 cm |
| Shipping Dimensions |
2.1 kg |
2.1 kg |
Regulatory Approvals |
| Emissions: |
FCC Part 15, Subpart B, Class A |
CFR47:2003, Chapter 1, Part 15 Subpart
B,(USA) Class A |
ICES-003,Issue 4, February 2004 (Canada) |
EN55022:1998 +A1:2000 + A2:2003 Class A |
EN61000-3-2 : 1995, Limits for Harmonic
Current Emissions |
EN61000-3-3 : 1995, Limits of Voltage
Fluctuations and Flicker |
| Immunity: |
EN55024:1998 + A1:2001 + A2:2003 |
EN61000-4-2: Electrostatic Discharge |
EN61000-4-3: RF Electromagnetic Field
Modulated |
EN61000-4-4: Fast Transients |
EN61000-4-5: Surge |
EN61000-4-6: RF Continuous Conducted |
EN61000-4-8: Power-Frequency Magnetic
Field |
EN61000-4-11: Voltage Dips and Voltage
Interruptions |
| Safety: |
IEC 60950-1, First Edition (2001-10)
and EN60950-1:2001, CB scheme. |
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL
60950-1,
First Edition April 1st 2003 (Recognized Component) |
| Medical Safety: |
EN 980:2003 : Graphical symbols for
use in the labeling of medical devices |
EN 1041:1998: Information supplied
by the manufacturer with medical devices |
IEC 60601-1: 3rd Edition, EN60601-1:1990,
+,
A1:1993, A2:1995,
+ A11 :1994, + A12 :1994,
+ A13 :1996: Medical
electrical equipment - General requirements for safety |
IEC 60601-1-1:2001: Medical Electrical
Equipment -
General requirements for safety - Collateral standard |
IEC 60601-1-2:2001, EN60601-1-2:2001
Medical electrical equipment - General requirements for safety - Collateral
standard - Electromagnetic compatibility - Requirements and tests |
UL 60601-1:2003: Medical electrical
equipment - General requirements for safety |
CSA C22.2-601.1-M90 with S1-94 and
B-90 (R2001)
AS/NZS 3200.1.0:1998 Medical electrical equipment -
General
requirements for safety |
| Other: |
RoHS - 2002/95/EC Directive |
WEEE - 2002/96/EC Directive |
CCATS - G052929 |
ECCN - 5A992A |
HTSUS Number: 8471.80.1000 |
| Warranty: |
Perle Lifetime Warranty |
* Features only apply when using "IOLAN" firmware
|
|
IOLAN MDC
|
IOLAN RJ45 Socket |
Function |
1 |
DTR (out) |
2 |
TxD (out) |
3 |
RxD (in) |
4 |
DCD (in) |
5 |
RTS (out) |
6 |
CTS (in) |
7 |
low current output (-12V)
(out) VLL * |
8 |
low current output (+12V) (out) VHH * |
9 |
GND |
10 |
Shield |
* applicable when operating as a plug
compatible
Philips DeviceLink controller
|