594M Configuration Utility Software Clarifications:
Procedure to Reset 594M into Factory Default
Issue
ID: AS400594M0005
Date: November 19, 2002
The
information in this article applies to:
- 594M
Configuration Utility software
SYMPTOMS
It
has been reported in the field that users are
not able to reset the 594M back into Factory
Default. This document has been created to in
order to clarify the procedure when using the
594M Configuration Utility program.
RESOLUTION
When
using the PC Utility program there are two ways
to put the 594M into Factory Default. You can
tell when the 594M is in Factory Default by
the flashing green “Ready” led on
the front panel.
You
will need a PC with PC Utility software loaded
on it and a serial cable connected from the
PC COM port to the 9 pin “UTIL”
connector on the back of the 594M.
Factory
Default from the Boot Menu
-
With the 594M powered off start the PC Utility
program on the PC, and then press the Enter
key to continue. At this point a pop-up message
should appear indicating that the PC is “Waiting
for a Serial Connection”.
-
Power up the 594M and a short menu with three
selections should be displayed. If the download
software screen appears instead press the
Esc key to get to the boot menu.
-
Cursor down to “Reset to Factory Default”
and press the Enter key. If a pop-up message
appears saying “Function not available”
you must try the alternate way to reset to
Factory Default. If a pop-up message saying
“Error in Communications” appears
try re-starting the PC Utility program without
powering off the 594M.
-
Cursor down to “Yes” and then
press the Space bar and then the Enter key
to confirm that you wish to put the unit into
Factory Default.
5. After several moments the 594M will boot
up into Factory Default. Press the Esc key
to exit the PC Utility program.
Factory
Default from Extended Diagnostics
-
With the 594M powered off start the PC Utility
program on the PC, and then press the Enter
key to continue. At this point a pop-up message
should appear indicating that the PC is “Waiting
for a Serial Connection”.
-
Power up the 594M and a short menu with three
selections should be displayed. If the download
software screen appears instead press the
Esc key to get to the boot menu.
-
Cursor down to “Extended Diagnostics”
and press the Enter key. A pop-up message
may appear informing you to reset the Controller
before continuing. If so, cursor to “Yes”
and press the Enter key.
-
Press the Enter key to begin the Extended
Diagnostic download. After downloading 100%
of the Extended Diagnostic code a long list
of menu items should appear.
-
Cursor down to “Reset to Factory Default”
and press the Enter key.
-
Cursor down to “Yes” and then
press the Space bar and then the Enter key
to confirm that you wish to put the unit into
Factory Default.
-
After several moments the 594M will boot up
into Factory Default. Press the Esc key to
exit the PC Utility program.
|