RIO
ports on LynxOS could not be used simultaneously
by different applications.
Issue
ID: SCRIO0002
Date: June 9, 2002
The
information in this article applies to:
- RIO
driver for LynxOS version 1.2.2
SYMPTOMS
The
RIO ports could not be simultaneously opened
by different applications. Also the RTA would
sometimes not be detected after power off/on
RESOLUTION
Engineering
has recognised the problem and has provided
the following upgrade to resolve this particular
issue. To update the RIO driver for LynxOS please
see the installation procedure in the RIO Users
Guide 5600034.
RIO
LynxOS 2.5.x and 3.0.x Driver - rio1224.tar.Z
|