IOLAN SDS-D Secure Device Servers
Serial to Ethernet Device Servers

- 1, 2 or 4 software selectable RS232/422/485 serial port interfaces
- 10/100 Ethernet
- Advanced security features for data encryption, user authentication and event management
Hardware Specifications - IOLAN SDS-D Device Servers
IOLAN SDS | IOLAN SDS T | IOLAN SDS P | |
---|---|---|---|
Processor | MPC852T, 66 Mhz, 87 MIPS | ||
Memory | |||
RAM MB | 32 | ||
Flash MB | 8 | ||
Interface Ports | |||
Number of Serial Ports | 1, 2 or 4 | ||
Serial Port Interface | Software selectable EIA232/422/485 on | ||
1 Port: DB9M, RJ45, DB25M or DB25F 2 Port: RJ45 4 Port: RJ45 |
1 Port: DB9M | 1 Port:RJ45 2 Port: RJ45 4 Port: RJ45 |
|
Sun / Solaris | Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime | ||
Serial Port Speeds | 50bps to 230Kbps with customizable baud rate support | ||
Data Bits | Configurable for 5,6,7 or 8-bit protocol support Use TruePort to transparently pass 9-bit serial data |
||
Parity | Odd, Even, Mark, Space, None | ||
Flow Control | Hardware, Software, Both, None | ||
Serial Port Protection | 15Kv Electrostatic Discharge Protection (ESD) | ||
Local Console Port | RS232 on Serial Port | ||
Network | 10Base-T / 100Base-TX Ethernet RJ45 | ||
Software selectable Ethernet speed 10/100 Auto | |||
Software selectable Half/Full/Auto duplex | |||
Ethernet Isolation | 1.5Kv Magnetic Isolation | ||
Power | IOLAN SDS | IOLAN SDS T | IOLAN SDS P |
Power Supply | 120 V AC (USA), 230V AC (International) Wall Power Adaptor included | Supplied with wired Barrell Connector 610mm (24 in) long | N/A |
Power Supply Options | Power via External power 9-30v DC, 4.8 Watts uses standard 5.5mm x 9.5mm x 2.1mm barrel socket, Power IN over serial cable |
||
Nominal Input Voltage | 12v DC / 24v DC | ||
Input Voltage Range | 9-30v DC | ||
Power IOLAN over Serial | 9-30v DC | ||
Power External Device via Serial Port | +5v DC regulated, 1W max | ||
Typical Power Consumption @ 12v DC (Watts) |
1 Port: 1.7 2 Port: 2.1 4 Port: 2.4 Does not include power for devices connected to serial port |
||
Indicators | |||
LEDs | Power/Ready | ||
Network Link | |||
Network Link activity | |||
Serial: Transmit and Receive data per port | |||
Environmental Specifications | IOLAN SDS | IOLAN SDS T | IOLAN SDS P |
Heat Output (BTU/HR) | 1 Port: 5.8 2 Port: 7.2 4 Port: 8.2 |
||
MTBF (Hours) | 1 Port: 123,192 2 Port: 188,596 4 Port: 150,124 |
1 Port:555,099 | 1 Port:344,227 2 Port:188,596 4 Port:138,467 |
Calculation model based on MIL-HDBK-217-FN2 @ 30 °C |
|||
Operating Temperature | 0C to 55C, 32F to 131F | -40C to 74C, -40F to 165F | 0C to 55C, 32F to 131F |
Storage Temperature | -40C to 66C, -40F to 150F | -40C to 85C, -40F to 185F | -40C to 66C, -40F to 150F |
Humidity | 5 to 95% (non condensing) for both storage and operation. | ||
Case | SECC Zinc plated sheet metal (1 mm) | ||
Ingress Protection Rating | IP40 | ||
Mounting | Wall or Panel mounting, DIN Rail mounting kit optional | ||
Product Weight and Dimensions | IOLAN SDS | IOLAN SDS T | IOLAN SDS P |
Weight | 1 Port: 0.23 kg (0.50 lbs) 2 Port: 0.23 kg (0.50 lbs) 4 Port: 0.35 kg (0.77 lbs) |
||
Dimensions (without mounting tabs) |
1 Port: 90 x 64 x 22 (mm), 3.6 x 2.5 x 0.87 (in) 2 Port: 90 x 64 x 22 (mm), 3.6 x 2.5 x 0.87 (in) 4 Port: 112 x 82 x 28 (mm), 4.4 x 3.2 x 1.1 (in) |
1 Port: 91 x 64 x 24 (mm) 3.6 x 2.5 x 0.92 (in) 2 Port: 91 x 64 x 24 (mm) 3.6 x 2.5 x 0.92 (in) 4 port: 112 x 82 x 28 (mm)M 4.4 x 3.2 x 1.1 (in) |
|
Dimensions with mounting tabs |
1 Port: 90 x 89 x 24 (mm), 3.6 x 3.5 x 0.87 (in) 2 Port: 90 x 89 x 24 (mm), 3.6 x 3.5 x 0.87 (in) 4 Port: 112 x 105 x 28 (mm), 4.4 x 4.2 x 1.1 (in) |
1 Port: 91 x 89 x 24 (mm) 3.6 x 3.5 x 0.92 (in) 1 Port: 91 x 89 x 24 (mm) 3.6 x 3.5 x 0.92 (in) 4 port: 112 x 105 x 28 (mm) 4.4 x 4.2 x 1.1 (in) |
|
Packaging | |||
Shipping Dimensions | 260 x 170 x 70 (mm), 10.2 x 6.7 x 2.8 (in) | ||
Shipping weight | 1 Port: 0.49 kg (1.1 lbs) 2 Port: 0.49 kg (1.1 lbs) 4 Port: 0.66 kg (1.5 lbs) |
1 Port: 0.42 kg (.92 lbs) | 1 Port: 0.4 kg (.88 lbs) 2 Port: 0.4 kg (.88 lbs) 4 Port: 0.54 kg (1.2 lbs) |
Regulatory Approvals | |||
Emissions | CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A | ||
ICES-003, Issue 4, February 2004 (Canada) | |||
CISPR 32:2015/EN 55032:2015 (Class A) | |||
EN55011 (CISPR11) | |||
EN61000-3-2 : 2010, Limits for Harmonic Current Emissions | |||
EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker | |||
Immunity | CISPR 24:2010/EN 55024:2010 | ||
EN61000-4-2: 2009 Electrostatic Discharge | |||
EN61000-4-3: 2006/A2:2010: RF Electromagnetic Field Modulated | |||
EN61000-4-4: 2004 Fast Transients | |||
EN61000-4-5: 2006 Surge | |||
EN61000-4-6: 2009 RF Continuous Conducted | |||
EN61000-4-8: Power-Frequency Magnetic Field | |||
Safety | UL/EN/IEC 62368-1 CAN/CSA C22.2 No. 62368-1 |
||
IEC 60950-1 (ed 2); am1 am2 and EN 60950-1: 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013 | |||
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, Second Edition | |||
Other | Reach, RoHS and WEEE Compliant | ||
CCATS - G168387 | |||
ECCN - 5A992 | |||
HTSUS Number: 8517.62.0020 | |||
Perle Limited Lifetime Warranty |
IOLAN RJ45 Serial Connector Pinout | ||||||
---|---|---|---|---|---|---|
|
Pinout | Direction | EIA-232 | EIA-422 | EIA-485 Full Duplex | EIA-485 Half Duplex |
1 | Power In (9-30V DC) | Power In (9-30V DC) | Power In (9-30V DC) | Power In (9-30V DC) | ||
2 | in | DCD | ||||
3 | out | RTS | TxD+ | TxD+ | TxD+/RxD+ | |
4 | in | DSR | ||||
5 | out | TxD | TxD- | TxD- | TxD-/RxD- | |
6 | in | RxD | RxD+ | RxD+ | ||
7 | GND | GND | GND | GND | ||
8 | in | CTS | RxD- | RxD- | ||
9 | out | DTR | ||||
10 | Power out | Power out | Power out | Power out | ||
Optional Perle adapters for use with straight thru CAT5 cabling |
IOLAN DB9M Serial Connector Pinout | ||||||
---|---|---|---|---|---|---|
|
Pinout | Direction | EIA-232 | EIA-422 Full Duplex | EIA-485 Full Duplex | EIA-485 Half Duplex |
1 | in | DCD | ||||
2 | in | RxD | RxD+ | RxD+ | ||
3 | out | TxD | TxD+ | TxD+ | DATA+ | |
4 | out | DTR | ||||
5 | GND | GND | GND | GND | ||
6 | in | DSR | RxD- | RxD- | ||
7 | out | RTS | ||||
8 | in | CTS | ||||
9 | TxD- | TxD- | DATA- |
IOLAN DB25F Socket Serial Connector Pinout | ||||||
---|---|---|---|---|---|---|
|
Pinout | Direction | EIA-232 | EIA-422 | EIA-485 Full Duplex | EIA-485 Half Duplex |
1 | Shield | Shield | Shield | Shield | ||
2 | in | RxD | ||||
3 | out | TxD | ||||
4 | in | CTS | ||||
5 | out | RTS | ||||
6 | out | DTR | ||||
7 | GND | GND | GND | GND | ||
8 | in | DCD | ||||
9 | Power out | Power out | Power out | Power out | ||
12 | Power In (9-30V DC) | Power In (9-30V DC) | Power In (9-30V DC) | Power In (9-30V DC) | ||
13 | RTS- | |||||
14 | RxD+ | RxD+ | ||||
15 | RxD- | RxD- | ||||
18 | CTS+ | |||||
19 | CTS- | |||||
20 | in | DSR | ||||
21 | TxD+ | TxD+ | DATA+ | |||
22 | TxD- | TxD- | DATA- | |||
25 | RTS+ |
IOLAN DB25M Serial Connector Pinout | ||||||
---|---|---|---|---|---|---|
|
Pinout | Direction | EIA-232 | EIA-422 | EIA-485 Full Duplex | EIA-485 Half Duplex |
1 | Shield | Shield | Shield | Shield | ||
2 | out | TxD | ||||
3 | in | RxD | ||||
4 | out | RTS | ||||
5 | in | CTS | ||||
6 | in | DSR | ||||
7 | GND | GND | GND | GND | ||
8 | in | DCD | ||||
9 | Power out | Power out | Power out | Power out | ||
12 | Power In(9-30V DC) | Power In(9-30V DC) | Power In(9-30V DC) | Power In(9-30V DC) | ||
13 | CTS- | |||||
14 | TxD+ | TxD+ | DATA+ | |||
15 | TxD- | TxD- | DATA- | |||
18 | RTS+ | |||||
19 | RTS- | |||||
20 | out | DTR | ||||
21 | RxD+ | RxD+ | ||||
22 | RxD- | RxD- | ||||
25 | CTS- |
Software Features - IOLAN SDS-D Device Servers
Serial Port Access | |
---|---|
Connect directly using Telnet / SSH by port and IP address | |
Connect with EasyPort menu by Telnet / SSH | |
Use an internet browser to access with HTTP or secure HTTPS via EasyPort Web menu | |
Java-free browser access to remote serial console ports via Telnet and SSH | |
Ports can be assigned a specific IP address ( aliasing ) | |
Multisession capability enables multiple users to access ports simultaneously | |
Multihost access enables multiple hosts/servers to share serial ports | |
Accessibility | |
In-band ( Ethernet ) and out-of-band ( dial-up modem ) support | |
Dynamic DNS enables users to find a console server from anywhere on the Internet | |
Domain name control through DHCP option 81 | |
IPV6 and IPV4 addressing support | |
Availability | |
Primary/Backup host functionality enables automatic connections to alternate host(s) | |
Security | |
SSH v1 and v2 | |
PCI DSS Compliance: TLS v1.2, TLS v1.1, TLS v1.0, SSL v3.0, SSL v2.0 | |
SSL Server and SSL client mode capability | |
SSL Peer authentication | |
IPSec VPN : NAT Traversal, ESP authentication protocol | |
SSH ciphers: AES-CTR, AES-GCM and ChaCha20-poly1305 | |
SSL encryption: AES-GCM, key exchange ECDH-ECDSA, HMAC SHA256, SHA384 | |
Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2) | |
Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96 | |
Key exchange: RSA, EDH-RSA, EDH-DSS, ADH | |
X.509 Certificate verification: RSA, DSA | |
Certificate authority (CA) list | |
Local database | |
RADIUS Authentication, Authorization and Accounting | |
TACACS+ Authentication, Authorization and Accounting | |
LDAP, NIS, Kerberos Authentication | |
RSA SecureID-agent or via RADIUS Authentication | |
SNMP v3 Authentication and Encryption support | |
IP Address filtering | |
Disable unused daemons | |
Active Directory via LDAP | |
Terminal Server | |
Telnet | |
SSH v1 and v2 | |
Rlogin | |
Auto session login | |
LPD, RCP printer | |
MOTD - Message of the day | |
Serial machine to Ethernet | |
Tunnel raw serial data across Ethernet - clear or encrypted | |
Raw serial data over TCP/IP | |
Raw serial data over UDP | |
Serial data control of packetized data | |
Share serial ports with multiple hosts/servers | |
Virtual modem simulates a modem connection - assign IP address by AT phone number | |
Virtual modem data can be sent over the Ethernet link with or without SSL encryption | |
TruePort com/tty redirector for serial based applications on Windows, Linux, Solaris, SCO, HP UX, NCR UNIX and AIX. For a complete list of all the latest drivers click here | |
TrueSerial packet technology provides the most authentic serial connections across Ethernet ensuring serial protocol integrity | |
RFC 2217 standard for transport of serial data and RS232 control signals | |
Customizable or fixed serial baud rates | |
Plug-ins allow customer or Perle provided plug-ins for special applications | |
Software Development Kit ( SDK ) available | |
Serial encapsulation of industrial protocols such as ModBus, DNP3 and IEC-870-5-101 | |
ModBus TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus TCP | |
Data logging will store serial data received when no active TCP session and forward to network peer once session re-established - 32K bytes circular per port | |
Console Management | |
Sun / Oracle Solaris Break Safe | |
Local port buffer viewing - 256K bytes per port | |
External port buffering via NFS, encrypted NFS and Syslog | |
Event notification | |
Manage AC power of external equipment using Perle RPS power management products | |
Clustering - central console server enables access ports across multiple console servers | |
Windows Server 2003/2008 EMS - SAC support GUI access to text-based Special Administrative Console | |
Ping watchdog probes enable customers to power cycle equipment with attached Perle RPS power switches in the event of an unresponsive networking gear | |
Remote Access | |
Dial, direct serial | PPP, PAP/CHAP, SLIP |
HTTP tunneling enables firewall-safe access to remote serial devices across the internet | |
Automatic DNS Update | Utilize DHCP Opt 81 to set IOLAN domain name for easy name management and with Dynamic DNS support , users on the Internet can access the device server by name without having to know its IP address. See Automatic DNS update support for details |
IPSEC VPN client/servers | Microsoft L2TP/IPSEC VPN client ( native to Windows XP) |
Microsoft IPSEC VPN Client ( native to Windows Vista ) | |
Cisco routers with IPSEC VPN feature set | |
Perle IOLAN SDS/STS and SCS models | |
OA&M ( Operations, Administration and Management ) | |
SNMP V3 - read and write, Perle MIB | |
Syslog | |
Perle Device Manager - Windows based utility for large scale deployments | |
Configurable default configuration | |
Installation Wizard | |
Set a Personalized Factory Default for your IOLANs | |
Protocols | |
IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, SFTP, SNTP, Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217, MSCHAP |